  • 系列名称:AAS-i2S-LMS空气质量流量传感器 - 用于排放控制和发动机管理
    系列描述:

     LMS质量空气流量传感器是专门为测量与车辆排放和发动机控制相关的空气量而开发的。根据热膜风速计的测量原理,空气质量流量传感器由成对布置的温度传感器和加热元件组成。这种布置允许双向测量,这使得可检测到回流和脉动。现代半导体热膜技术可确保快速响应时间以及在整个生命周期中进行可靠,稳定的测量。特殊应用的质量空气流量传感器的校准还保证了高精度,完全符合各自系统的特性曲线。其紧凑的设计(带有法兰安装件)不仅可以轻松集成到流道(管道)中,而且还保证了在各种系统中的灵活安装。LMS还可以可选地配备一个温度传感器,用于介质温度的附加测量。 

    产品应用

    • 车辆的排放和发动机控制

    • 加热系统

    • 空调技术应用

    • 过程控制

    • 气体流量监测

    • 过滤网监测

     

    Key features

    Benefits

    Semi-conductor hot film measurement element

    · Fast response time

     

    · Reliable, stable measurement over the entire life cycle

    Individual electronic calibration

    · High level of accuracy

     

    · Application-specific characteristic curves

     

    · Diagnostic options

    Integrated temperature sensor

    · Simultaneous media temperature measurement

    Compact and robust design with flange connection

    · Simple and flexible integration in flow channels(pipes) and a wide variety of systems

     

    · Twist-proof installation

    Bi-directional flow measurement

    · Detection of backflows and pulsations

     

    Measurement ranges

     

    Air mass

    0 – 50…0 – 3,000 kg/h1)

    Temperature

    -30…120°C

     

     

    Electrical characteristics

     

    Supply voltage

    12 V (9…17 V)

    Electrical characteristics

     

    Supply voltage

    12 V (9…17 V)

    Air mass output signal

    1…4.85 V, ratiometric to the reference voltage (main flow)

     

    1…0.33 V, ratiometric to the reference voltage (backflow)

    Temperature output signal

    NTC resistance output 2 k (25°C)

    Reference voltage

    5 V ± 0.2 V

    Overvoltage protection

    17 V

    Reverse polarity protection

    17 V

    Diagnostic areas (detected sensor error)

    < 4% and > 97.5% of the reference voltage

     

    Accuracy

     

    Total air mass error

    2% of the measurement value (25°C) 4)

    Total temperature error

    ± 1% (25°C), corresponding to the NTC characteristic curve

    Response time (t63)

    < 20 msec

     

    Environmental conditions

     

    Ambient temperature range

    -30…120°C

    Operating temperature range

    -30…85°C

    Media compatibility

    Air

    ESD (ISO/TR 10605)

    4 kV to contacts

    EMC (ISO 11452-5)

    100 V/m (Strip line)