PMU-P
with asynchronous ASCII transmission protocol
calibrated for relative humidity and temperature
exchangeable, plug-in design
housing made of plastic
Accuracy
Humidity ± 1,5 %rh 10...90 %rh at 25 °C
Temperature ± 0,15 K at 25 °C
The exchangeable digital sensor PMU-P is equipped with the Mela humidity measuring element humidity measuring element FE09/4. Protected by a PTFE pocket filter, the measuring element measures the air humidity. The pocket filter consists of porous vapour-permeable material and protects the sensor element from most dirt, dust and pollutants. The electronics and the plug contacts on the back are ex- trusion-coated with plastic to make them watertight.